Welcome to Iightstrade.com!

Low and medium voltage power cables

MOQ : piece

Lead Time : Days

Product details

Supply Ability

  • Warranty(Year):1 Year

Product Specifications

Product Description

  

Low and medium voltage power cables  

 

salesjycable[at]hotmail[dot]com

Type,

YJV YJV22 YJV32 YJV62

cores,

1-6

Jacket material,

PVC

Wire maximum diameter,

10-425 mm

Insulation thickness,

1-5 mm  

Nominal cross section,

1-700 mm2

Line core material,

Red copper wire

Coltage grade,

Low and medium voltage power cables 35kv and below

 

 

Insulation material,

Plastic insulated power cable

 

 

 

 

Production range:

type

cores

Rated voltage KV

0.6/1

1.8/3

3.6/6,6/6

6/10,8.7/10

8.7/15-12/20

18/20-26/35

Conductive wire core nominal section MM2

YJV
YJLV

1

1.5-800

10-800

25-1200

25-1200

35-1200

50-1200

3

1.5-300

10-300

25-300

25-300

35-300

-

4

4-240

-

-

-

-

-

YJV
YJLV

1

2.5-1000

10-1000

25-1200

25-1200

35-1200

50-1200

3

2.5-300

10-300

20-300

25-300

35-300

-

4

-

-

-

-

-

-

YJV22
YJLV22

-

-

-

-

-

-

-

3

4-300

4-300

25-300

25-300

35-300

-

4

4-240

4-240

-

-

-

-

YJV23
YJLV23

-

-

-

-

-

-

-

3

4-300

4-300

25-300

25-300

35-300

-

4

4-240

4-240

-

-

-

 

 

Type

Description

YJV

Copper core crosslinked polyethylene insulated PVC sheathed power cable

YJLV

Aluminium crosslinked polyethylene insulated PVC sheathed power cable

YJV22

Copper core crosslinked polyethylene insulation tape armored PVC sheathed power cable

YJLV22

Aluminium crosslinked polyethylene insulation tape armored PVC sheathed power cable

 

Operating characteristic

1.Cable highest long-termworking temperature is 90 C

2.Cable the ambienttemperature under installation should not below 0 C, cable bending radiusshould be more than twenty times of cable diameter

3.Incase of short circuit, the highest temperature of the conductor shall not bemore than 250 C, duration is no more than 5 seconds

4.Laying temperature shallnot be lower than 0 C

5.Short circuit, the highesttemperature of the conductor shall not be more than 160 C, duration is no morethan 5 seconds

6.Cable used for ratedvoltage 1.8/3 0.6/1, 3.6/6, 6/6, 6/10, 8.7/10, 8.7/15, 12/20, 21/35, 26/35 kv,power transmission and distribution system

7.YJV YJLV suitable forindoor and outdoor installation, can withstand certain laying traction, butunable to bear external mechanical forces of situations. Single core cable arenot allowed in the pipe laying in ferromagnetic materials. YJV22, YJLV22suitable for buried laying, able to bear external mechanical forces effect, butunable to bear large pulling force

 

 

 

Oil resistantcable:used for numerical control machine tool equipment electrical connection

Waterproof cable: used for outdoor, undergroundpipelines, CMC channel and humidity larger environment

Rat termite cable: used for importantsignal transmission cable, power cable, can effectively prevent the rats, antsand insects chewing on cable

Resistance tolow temperature cable:used for outdoor, cold storage equipment working environment, the minimumresistance low temperature - degrees, in low temperature environment cable canstill keep soft condition, no crack, convenient operation.

Environmentalprotection cable: theenvironmental protection plastics, widely used in environmental protectionrequirements of strict place.

Flameretardant cable: the flameretardant plastic, in case of fire can effectively prevent fire spread alongthe wire.

 

Integratedcable: accordingto the customer request or sample production lines, the various equipment line,line integrated in a piece of wire inside, plus sheath of protection wiringbeautiful and extend cable service life. According to the different useenvironment can choose oil resistant sheath, waterproof jacket, resistance tolow temperature sheath, ring protective sleeve, general PVC sheathed, elasticsheath, flame retardant sheath and so on many kinds of types for wiringoperation to provide adequate agility and convenience

 

 

 

 

  

You May Like